Warning: Use of undefined constant X - assumed 'X' (this will throw an Error in a future version of PHP) in /home/tneutron/public_html/wp-content/themes/jarida_disabled/functions.php on line 7
" /> Instalasi Pembangkit Listrik – Page 2 – TN Blogs
Notice: Undefined index: font in /home/tneutron/public_html/wp-content/themes/jarida_disabled/functions/common-scripts.php on line 150

Notice: Undefined index: font in /home/tneutron/public_html/wp-content/themes/jarida_disabled/functions/common-scripts.php on line 150

Notice: Undefined index: font in /home/tneutron/public_html/wp-content/themes/jarida_disabled/functions/common-scripts.php on line 150
Home > Instalasi Pembangkit Listrik (page 2)

Instalasi Pembangkit Listrik

Wiring Secondary Section

Describe secondary wiring electrical circuits in the secondary side of the current transformer and voltage transformer on the low voltage side. Currents and voltages are derived from current transformers and voltage transformers are used in addition to measurement is also used to operate relays to for purposes of protection. Then close the relay contacts in the direct current circuit from ...

Read More »

System Protection

Disorder that often occurs is the short circuit between phase or phase to ground and between the two. Short circuit can cause large currents that can damage equipment or security systems that needed protection system. The current flowing to the trip coil (TC) is the direct current from the storage battery. Storage battery has an important role in the protection ...

Read More »

Rel Protection (Busbar)

Rel (busbar) on the electrical center is a vital part of the installation, meaning that in the event of disruption or damage to rail would be a great result for the operation of the electrical center is concerned because power can be channeled. When something like this happens on a large power center in interconnect systems, then this may disrupt ...

Read More »

Principle Of Electromechanical Relays

At a certain load current value corresponding calibration relays, contact C closes, current flows kekumparan disc (induction) A rotating disc that moves close pal D and E so that the trip coil contact (IC) and the current gets mentrip PMT. The time delay relay is done by setting the distance between the contacts pal D E. At a certain value ...

Read More »

System Excitacy

Figure II.97 shows the electrical circuit of the generator excitacy large (above 50 MVA) using a 2-level amplifier current generator (exciter). The first generator amplifier, is direct current generator that generates current relationship shunt generator amplifier for the second amplifier. Amplifier generator (exciter) for synchronous generator is the main generator power taken.   Figure II.97 main generator voltage setting with ...

Read More »

Breaker Energy Developments

The development of circuit breaker construction is as follows: a. Disconnect power from the air Tapered shape, the electric arc will arise (jump) in the first tapered portion at the time of the switch contacts separate. Because the specific gravity of the electric arc is smaller than the density of air, electric arc will float to the top so that ...

Read More »