{"id":4974,"date":"2023-04-17T01:07:01","date_gmt":"2023-04-16T18:07:01","guid":{"rendered":"http:\/\/www.tneutron.net\/blogs\/?p=4974"},"modified":"2023-04-12T08:53:10","modified_gmt":"2023-04-12T01:53:10","slug":"flow-control-valves","status":"publish","type":"post","link":"https:\/\/www.tneutron.net\/blogs\/flow-control-valves\/","title":{"rendered":"Flow Control Valves"},"content":{"rendered":"<ul style=\"margin-bottom: 0cm; margin-top: 0cm;\" type=\"disc\">\n<li style=\"margin: 0cm 0cm 0pt;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Times New Roman;\">Valves that impede the flow pipe to control the oil flow volume in order to speed hydraulic motors and cylinders can be controlled on a fixed displacement hydraulic pump is used.<\/span><\/span><\/li>\n<li style=\"margin: 0cm 0cm 0pt;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Times New Roman;\">Throttle<\/span><\/span><\/li>\n<li style=\"margin: 0cm 0cm 0pt;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Times New Roman;\">Valve which controls the flow by blocking resistance in the valve, but changes according to the change of pressure before and behind the valve.<\/span><\/span> <span style=\"font-size: 12pt;\"><span style=\"font-family: Times New Roman;\">This valve can be set in a simple (niddle valve) or fixed barriers to the flow (orifice).<\/span><\/span><\/li>\n<li style=\"margin: 0cm 0cm 0pt;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Times New Roman;\">Flow control valve with pressure compensation<\/span><\/span><\/li>\n<li style=\"margin: 0cm 0cm 0pt;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Times New Roman;\">This valve has a pressure compensation mechanism to keep the pre-design pressures difference before and behind the throttle valve.<\/span><\/span> <span style=\"font-size: 12pt;\"><span style=\"font-family: Times New Roman;\">By doing this, the flow volume can be kept constant regardless of fluctuations in pressure before and behind the valve.<\/span><\/span> <span style=\"font-size: 12pt;\"><span style=\"font-family: Times New Roman;\">Design orifice pressure compensation will normally provide yagn viscosity changes due to temperature.<\/span><\/span> <span style=\"font-size: 12pt;\"><span style=\"font-family: Times New Roman;\">Some designs may have springs made \u200b\u200bof bi-metal that will compensate for temperature changes.<\/span><\/span><\/li>\n<\/ul>\n<div style=\"margin: 0cm 0cm 0pt;\"><span style=\"font-family: Times New Roman;\"><span style=\"font-size: 12pt;\">\u00a0<\/span><\/span> <a href=\"http:\/\/www.tneutron.net\/blogs\/wp-content\/uploads\/sites\/10\/2015\/04\/clip_image001_thumb-8.jpg\"><img loading=\"lazy\" decoding=\"async\" style=\"margin: 0px; padding-left: 0px; padding-right: 0px; padding-top: 0px; border-width: 0px;\" title=\"clip_image001\" src=\"http:\/\/www.tneutron.net\/blogs\/wp-content\/uploads\/sites\/10\/2015\/04\/clip_image001_thumb-8.jpg\" alt=\"clip_image001\" width=\"456\" height=\"309\" border=\"0\" \/><\/a><\/div>\n<div style=\"margin: 0cm 0cm 0pt;\">Figure 4.82 The valves control the flow with pressure compensation<\/p>\n<p><strong>Flow divider valve<\/strong><br \/>\nValve which divides the oil flowing into the two hydraulic flow which has a different pressure than the source of power regardless of the pressure flow. This type of valve can be used to divide the flow of the hydraulic pump or source into two separate chain crawler tractor steering. Both of these series can operate, independently of the other. In industrial applications, where the flow should be divided with a very accurate or if the flow is divided into more than two streams, then there must be some means of rotary flow divider installed and connected to the hydraulic motor.<\/p>\n<p><strong>Directional control valve<\/strong><br \/>\nThe drain valve or stop the flow of oil flow so that the actuator can be operated to come forward or back and hold it in the middle, and dioperasikn with external power (manpower, solenoid or mechanical power).<br \/>\nDirectional valves are manufactured with many configurations depending on the number of doors and operating position but the valve is commonly used for the hydraulic circuit will be the valve spool type 2 posisis &#8211; 4 way (2\/4) or 3 positions &#8211; 4 way (3\/4). In earthmoving machinery, valves directionalnya for blade, dump body, buscket could have 4 positions (4\/4), the next position will provide a full cylinder float.<\/p>\n<p><strong>Common center position on the 4\/3 way valve<\/strong><br \/>\nFigure below shows about 4\/3 way valve with a wide range of middle position and is accompanied by a brief description of the method of operation:<br \/>\nCenter position valve 4\/3-way &#8220;recirculation pump&#8221; (tandem center).<\/div>\n<div style=\"margin: 0cm 0cm 0pt;\"><span style=\"font-family: Times New Roman;\"><span style=\"font-size: 12pt;\">\u00a0<\/span><\/span> <a href=\"http:\/\/www.tneutron.net\/blogs\/wp-content\/uploads\/sites\/10\/2015\/04\/clip_image002_thumb-10.jpg\"><img loading=\"lazy\" decoding=\"async\" style=\"margin: 0px; padding-left: 0px; padding-right: 0px; padding-top: 0px; border-width: 0px;\" title=\"clip_image002\" src=\"http:\/\/www.tneutron.net\/blogs\/wp-content\/uploads\/sites\/10\/2015\/04\/clip_image002_thumb-10.jpg\" alt=\"clip_image002\" width=\"289\" height=\"146\" border=\"0\" \/><\/a><\/div>\n<div style=\"margin: 0cm 0cm 0pt;\">Ports P and T are connected: sehungga, pump discharge valve is only possible as opposed to a minimum and the resistance force (circulation pump = energy savings).<br \/>\nCenter position valve 4\/3-way &#8220;closed&#8221; (flashlight closed).<\/div>\n<div style=\"margin: 0cm 0cm 0pt;\"><span style=\"font-family: Times New Roman;\"><span style=\"font-size: 12pt;\">\u00a0<\/span><\/span> <a href=\"http:\/\/www.tneutron.net\/blogs\/wp-content\/uploads\/sites\/10\/2015\/04\/clip_image003_thumb-8.jpg\"><img loading=\"lazy\" decoding=\"async\" style=\"margin: 0px; padding-left: 0px; padding-right: 0px; padding-top: 0px; border-width: 0px;\" title=\"clip_image003\" src=\"http:\/\/www.tneutron.net\/blogs\/wp-content\/uploads\/sites\/10\/2015\/04\/clip_image003_thumb-8.jpg\" alt=\"clip_image003\" width=\"289\" height=\"146\" border=\"0\" \/><\/a><\/div>\n<div style=\"margin: 0cm 0cm 0pt;\">Kempat this port closed: the placement of the power components is given, which in case of a slide valve, leaking oil is expected to position the components in the long term.<br \/>\nMiddle position &#8220;H&#8221; valve 4\/3-way (open flashlight).<\/p>\n<p>Four ports that interconnect: relif power components and hydraulic pump (eg. The cylinder can be changed).<br \/>\nCenter position valve 4\/3-way &#8220;power lines exhausted&#8221; (floating flashlight).<\/p><\/div>\n<div style=\"margin: 0cm 0cm 0pt;\"><span style=\"font-family: Times New Roman;\"><span style=\"font-size: 12pt;\">\u00a0<\/span><\/span> <a href=\"http:\/\/www.tneutron.net\/blogs\/wp-content\/uploads\/sites\/10\/2015\/04\/clip_image004_thumb-7.jpg\"><img loading=\"lazy\" decoding=\"async\" style=\"margin: 0px; padding-left: 0px; padding-right: 0px; padding-top: 0px; border-width: 0px;\" title=\"clip_image004\" src=\"http:\/\/www.tneutron.net\/blogs\/wp-content\/uploads\/sites\/10\/2015\/04\/clip_image004_thumb-7.jpg\" alt=\"clip_image004\" width=\"289\" height=\"146\" border=\"0\" \/><\/a><\/div>\n<div style=\"margin: 0cm 0cm 0pt;\">Port T is connected to the A and B: Hose wasted; cylinder changed. No reliefs pump. Center position valve 4\/3-way &#8220;by-pass&#8221; (flashlight regeneration).<\/div>\n<div style=\"margin: 0cm 0cm 0pt;\"><span style=\"font-family: Times New Roman;\"><span style=\"font-size: 12pt;\">\u00a0<\/span><\/span> <a href=\"http:\/\/www.tneutron.net\/blogs\/wp-content\/uploads\/sites\/10\/2015\/04\/clip_image005_thumb-4.jpg\"><img loading=\"lazy\" decoding=\"async\" style=\"padding-left: 0px; padding-right: 0px; padding-top: 0px; border-width: 0px;\" title=\"clip_image005\" src=\"http:\/\/www.tneutron.net\/blogs\/wp-content\/uploads\/sites\/10\/2015\/04\/clip_image005_thumb-4.jpg\" alt=\"clip_image005\" width=\"289\" height=\"146\" border=\"0\" \/><\/a><\/div>\n<div style=\"margin: 0cm 0cm 0pt;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Times New Roman;\">Port P is connected to A and B: After a given pressure, ie.<\/span><\/span> <span style=\"font-size: 12pt;\"><span style=\"font-family: Times New Roman;\">for differential circuit.<\/span><\/span><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Valves that impede the flow pipe to control the oil flow volume in order to speed hydraulic motors and cylinders<\/p>\n","protected":false},"author":1,"featured_media":5401,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"colormag_page_container_layout":"default_layout","colormag_page_sidebar_layout":"default_layout","footnotes":""},"categories":[25],"tags":[7856,7853,7858,7857,7861,7859,7855,7860,7854],"class_list":["post-4974","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-komponen-alat-berat","tag-flow-control-valves","tag-flow-control-valves-hydraulic","tag-flow-control-valves-pdf","tag-flow-control-valves-pneumatic","tag-flow-control-valves-ppt","tag-flow-control-valves-symbols","tag-flow-control-valves-types","tag-flow-control-valves-uk","tag-flow-control-valves-water"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Flow Control Valves - TN Blogs<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.tneutron.net\/blogs\/flow-control-valves\/\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:title\" content=\"Flow Control Valves - TN Blogs\" \/>\n<meta name=\"twitter:description\" content=\"Valves that impede the flow pipe to control the oil flow volume in order to speed hydraulic motors and cylinders\" \/>\n<meta name=\"twitter:creator\" content=\"@t_neutron\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Taufiqullah\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/blogs\\\/flow-control-valves\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/blogs\\\/flow-control-valves\\\/\"},\"author\":{\"name\":\"Taufiqullah\",\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/blogs\\\/#\\\/schema\\\/person\\\/b57f791b694136047454bb6ac5cbe375\"},\"headline\":\"Flow Control Valves\",\"datePublished\":\"2023-04-16T18:07:01+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/blogs\\\/flow-control-valves\\\/\"},\"wordCount\":538,\"image\":{\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/blogs\\\/flow-control-valves\\\/#primaryimage\"},\"thumbnailUrl\":\"\",\"keywords\":[\"flow control valves\",\"flow control valves hydraulic\",\"flow control valves pdf\",\"flow control valves pneumatic\",\"flow control valves ppt\",\"flow control valves symbols\",\"flow control valves types\",\"flow control valves uk\",\"flow control valves water\"],\"articleSection\":[\"Komponen Alat Berat\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/blogs\\\/flow-control-valves\\\/\",\"url\":\"https:\\\/\\\/www.tneutron.net\\\/blogs\\\/flow-control-valves\\\/\",\"name\":\"Flow Control Valves - TN Blogs\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/blogs\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/blogs\\\/flow-control-valves\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/blogs\\\/flow-control-valves\\\/#primaryimage\"},\"thumbnailUrl\":\"\",\"datePublished\":\"2023-04-16T18:07:01+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/blogs\\\/#\\\/schema\\\/person\\\/b57f791b694136047454bb6ac5cbe375\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/blogs\\\/flow-control-valves\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.tneutron.net\\\/blogs\\\/flow-control-valves\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/blogs\\\/flow-control-valves\\\/#primaryimage\",\"url\":\"\",\"contentUrl\":\"\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/blogs\\\/flow-control-valves\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.tneutron.net\\\/blogs\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Flow Control Valves\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/blogs\\\/#website\",\"url\":\"https:\\\/\\\/www.tneutron.net\\\/blogs\\\/\",\"name\":\"TN Blogs\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.tneutron.net\\\/blogs\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/blogs\\\/#\\\/schema\\\/person\\\/b57f791b694136047454bb6ac5cbe375\",\"name\":\"Taufiqullah\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/dcdf36434717ce57bea7f17eb3c140a2ff8def45941b720aa8fc1cccd6cdd505?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/dcdf36434717ce57bea7f17eb3c140a2ff8def45941b720aa8fc1cccd6cdd505?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/dcdf36434717ce57bea7f17eb3c140a2ff8def45941b720aa8fc1cccd6cdd505?s=96&d=mm&r=g\",\"caption\":\"Taufiqullah\"},\"description\":\"Taufiqullah\",\"sameAs\":[\"http:\\\/\\\/www.tneutron.net\",\"https:\\\/\\\/x.com\\\/t_neutron\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Flow Control Valves - TN Blogs","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.tneutron.net\/blogs\/flow-control-valves\/","twitter_card":"summary_large_image","twitter_title":"Flow Control Valves - TN Blogs","twitter_description":"Valves that impede the flow pipe to control the oil flow volume in order to speed hydraulic motors and cylinders","twitter_creator":"@t_neutron","twitter_misc":{"Written by":"Taufiqullah","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.tneutron.net\/blogs\/flow-control-valves\/#article","isPartOf":{"@id":"https:\/\/www.tneutron.net\/blogs\/flow-control-valves\/"},"author":{"name":"Taufiqullah","@id":"https:\/\/www.tneutron.net\/blogs\/#\/schema\/person\/b57f791b694136047454bb6ac5cbe375"},"headline":"Flow Control Valves","datePublished":"2023-04-16T18:07:01+00:00","mainEntityOfPage":{"@id":"https:\/\/www.tneutron.net\/blogs\/flow-control-valves\/"},"wordCount":538,"image":{"@id":"https:\/\/www.tneutron.net\/blogs\/flow-control-valves\/#primaryimage"},"thumbnailUrl":"","keywords":["flow control valves","flow control valves hydraulic","flow control valves pdf","flow control valves pneumatic","flow control valves ppt","flow control valves symbols","flow control valves types","flow control valves uk","flow control valves water"],"articleSection":["Komponen Alat Berat"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.tneutron.net\/blogs\/flow-control-valves\/","url":"https:\/\/www.tneutron.net\/blogs\/flow-control-valves\/","name":"Flow Control Valves - TN Blogs","isPartOf":{"@id":"https:\/\/www.tneutron.net\/blogs\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.tneutron.net\/blogs\/flow-control-valves\/#primaryimage"},"image":{"@id":"https:\/\/www.tneutron.net\/blogs\/flow-control-valves\/#primaryimage"},"thumbnailUrl":"","datePublished":"2023-04-16T18:07:01+00:00","author":{"@id":"https:\/\/www.tneutron.net\/blogs\/#\/schema\/person\/b57f791b694136047454bb6ac5cbe375"},"breadcrumb":{"@id":"https:\/\/www.tneutron.net\/blogs\/flow-control-valves\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.tneutron.net\/blogs\/flow-control-valves\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.tneutron.net\/blogs\/flow-control-valves\/#primaryimage","url":"","contentUrl":""},{"@type":"BreadcrumbList","@id":"https:\/\/www.tneutron.net\/blogs\/flow-control-valves\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.tneutron.net\/blogs\/"},{"@type":"ListItem","position":2,"name":"Flow Control Valves"}]},{"@type":"WebSite","@id":"https:\/\/www.tneutron.net\/blogs\/#website","url":"https:\/\/www.tneutron.net\/blogs\/","name":"TN Blogs","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.tneutron.net\/blogs\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/www.tneutron.net\/blogs\/#\/schema\/person\/b57f791b694136047454bb6ac5cbe375","name":"Taufiqullah","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/dcdf36434717ce57bea7f17eb3c140a2ff8def45941b720aa8fc1cccd6cdd505?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/dcdf36434717ce57bea7f17eb3c140a2ff8def45941b720aa8fc1cccd6cdd505?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/dcdf36434717ce57bea7f17eb3c140a2ff8def45941b720aa8fc1cccd6cdd505?s=96&d=mm&r=g","caption":"Taufiqullah"},"description":"Taufiqullah","sameAs":["http:\/\/www.tneutron.net","https:\/\/x.com\/t_neutron"]}]}},"_links":{"self":[{"href":"https:\/\/www.tneutron.net\/blogs\/wp-json\/wp\/v2\/posts\/4974","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.tneutron.net\/blogs\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.tneutron.net\/blogs\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.tneutron.net\/blogs\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.tneutron.net\/blogs\/wp-json\/wp\/v2\/comments?post=4974"}],"version-history":[{"count":1,"href":"https:\/\/www.tneutron.net\/blogs\/wp-json\/wp\/v2\/posts\/4974\/revisions"}],"predecessor-version":[{"id":9215,"href":"https:\/\/www.tneutron.net\/blogs\/wp-json\/wp\/v2\/posts\/4974\/revisions\/9215"}],"wp:attachment":[{"href":"https:\/\/www.tneutron.net\/blogs\/wp-json\/wp\/v2\/media?parent=4974"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.tneutron.net\/blogs\/wp-json\/wp\/v2\/categories?post=4974"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.tneutron.net\/blogs\/wp-json\/wp\/v2\/tags?post=4974"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}