{"id":1394,"date":"2024-06-28T01:30:32","date_gmt":"2024-06-27T18:30:32","guid":{"rendered":"http:\/\/www.tneutron.net\/elektro\/?p=1394"},"modified":"2024-06-27T14:24:27","modified_gmt":"2024-06-27T07:24:27","slug":"ohmmeter-paralel","status":"publish","type":"post","link":"https:\/\/www.tneutron.net\/elektro\/ohmmeter-paralel\/","title":{"rendered":"Ohmmeter Paralel"},"content":{"rendered":"<p>Dalam keadaan tidak dipergunakan, saklar S harus dibuka agar batere V tidak lekas menjadi lemah. Bila ohmmeter dipergunakan, maka saklar S ditutup.Mula-mula diambil RX = tak terhingga atau A-B dalam keadaan terbuka, sehingga diperoleh arus melalui M + IM. Pada keadaan ini pontensiometer R2 diatur agar arus melalui M mencapai harga maksimum (skala penuh), sehingga:<br \/>\n<a href=\"http:\/\/www.tneutron.net\/elektro\/wp-content\/uploads\/sites\/2\/2016\/04\/image-15.png\"><img loading=\"lazy\" decoding=\"async\" style=\"background-image: none; padding-top: 0px; padding-left: 0px; margin: 0px; display: inline; padding-right: 0px; border-width: 0px;\" title=\"image\" src=\"http:\/\/www.tneutron.net\/elektro\/wp-content\/uploads\/sites\/2\/2016\/04\/image_thumb-15.png\" alt=\"image\" width=\"137\" height=\"42\" border=\"0\" \/><\/a><\/p>\n<p>Kedudukan R2 jangan diubah lagi sehingga selalu terpenuhi persamaan Imaks di atas dengan demikian akan diperoleh bahwa skala dengan RX = tak terhingga terletak di sebelah kanan. Untuk RX = nol atau A-B dihubungsingkatkan maka tidak ada arus melalui M atau . Jadi skala nol ohm terletak di sebelah kiri. Apakah perbedaan dengan ohmmeter seri ?<br \/>\n<a href=\"http:\/\/www.tneutron.net\/elektro\/wp-content\/uploads\/sites\/2\/2016\/04\/image-17.png\"><img loading=\"lazy\" decoding=\"async\" style=\"background-image: none; padding-top: 0px; padding-left: 0px; display: inline; padding-right: 0px; border-width: 0px;\" title=\"image\" src=\"http:\/\/www.tneutron.net\/elektro\/wp-content\/uploads\/sites\/2\/2016\/04\/image_thumb-17.png\" alt=\"image\" width=\"359\" height=\"161\" border=\"0\" \/><\/a><br \/>\n<strong>Kurva Kalibrasi<\/strong><\/p>\n<p>Bila dipasang resistansi RX pada rangkaian pada Gambar 5.60 maka dapat dihitung arus melalui M:<br \/>\n<a href=\"http:\/\/www.tneutron.net\/elektro\/wp-content\/uploads\/sites\/2\/2016\/04\/image-19.png\"><img loading=\"lazy\" decoding=\"async\" style=\"background-image: none; padding-top: 0px; padding-left: 0px; display: inline; padding-right: 0px; border-width: 0px;\" title=\"image\" src=\"http:\/\/www.tneutron.net\/elektro\/wp-content\/uploads\/sites\/2\/2016\/04\/image_thumb-18.png\" alt=\"image\" width=\"209\" height=\"63\" border=\"0\" \/><\/a><\/p>\n<p>Dari persamaan IM di atas dapat dibuat kurva kalibrasi yaitu grafik RX sebagai fungsi IM. Berikut, diperlihatkan contoh bentuk kurva kalibrasi suatu ohmmeter paralel.<br \/>\n<a href=\"http:\/\/www.tneutron.net\/elektro\/wp-content\/uploads\/sites\/2\/2016\/04\/image-20.png\"><img loading=\"lazy\" decoding=\"async\" style=\"background-image: none; padding-top: 0px; padding-left: 0px; display: inline; padding-right: 0px; border-width: 0px;\" title=\"image\" src=\"http:\/\/www.tneutron.net\/elektro\/wp-content\/uploads\/sites\/2\/2016\/04\/image_thumb-20.png\" alt=\"image\" width=\"244\" height=\"174\" border=\"0\" \/><\/a><br \/>\nGambar 8.9 Kurva Kalibrasi Ohmmeter Paralel<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Dalam keadaan tidak dipergunakan, saklar S harus dibuka agar batere V tidak lekas menjadi lemah. Bila ohmmeter dipergunakan, maka saklar S ditutup.Mula-mula diambil RX = tak terhingga atau A-B dalam keadaan terbuka, sehingga diperoleh arus melalui M + IM. Pada keadaan ini pontensiometer R2 diatur agar arus melalui M mencapai harga maksimum (skala penuh), sehingga: &#8230;<\/p>\n","protected":false},"author":1,"featured_media":1393,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1881],"tags":[1912,1910,1911],"class_list":["post-1394","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-pengukuran-resistan-listrik","tag-ohmmeter-kalibrasi","tag-ohmmeter-paralel","tag-ohmmeter-tipe-paralel"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Ohmmeter Paralel - TN Elektro<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.tneutron.net\/elektro\/ohmmeter-paralel\/\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:title\" content=\"Ohmmeter Paralel - TN Elektro\" \/>\n<meta name=\"twitter:description\" content=\"Dalam keadaan tidak dipergunakan, saklar S harus dibuka agar batere V tidak lekas menjadi lemah. Bila ohmmeter dipergunakan, maka saklar S ditutup.Mula-mula diambil RX = tak terhingga atau A-B dalam keadaan terbuka, sehingga diperoleh arus melalui M + IM. Pada keadaan ini pontensiometer R2 diatur agar arus melalui M mencapai harga maksimum (skala penuh), sehingga: ...\" \/>\n<meta name=\"twitter:image\" content=\"https:\/\/www.tneutron.net\/elektro\/wp-content\/uploads\/sites\/2\/2016\/04\/image_thumb-20.png\" \/>\n<meta name=\"twitter:creator\" content=\"@t_neutron\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Taufiqullah\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/elektro\\\/ohmmeter-paralel\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/elektro\\\/ohmmeter-paralel\\\/\"},\"author\":{\"name\":\"Taufiqullah\",\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/elektro\\\/#\\\/schema\\\/person\\\/b57f791b694136047454bb6ac5cbe375\"},\"headline\":\"Ohmmeter Paralel\",\"datePublished\":\"2024-06-27T18:30:32+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/elektro\\\/ohmmeter-paralel\\\/\"},\"wordCount\":153,\"image\":{\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/elektro\\\/ohmmeter-paralel\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.tneutron.net\\\/elektro\\\/wp-content\\\/uploads\\\/sites\\\/2\\\/2016\\\/04\\\/image_thumb-20.png\",\"keywords\":[\"Ohmmeter Kalibrasi\",\"Ohmmeter Paralel\",\"ohmmeter tipe paralel\"],\"articleSection\":[\"Pengukuran Resistan Listrik\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/elektro\\\/ohmmeter-paralel\\\/\",\"url\":\"https:\\\/\\\/www.tneutron.net\\\/elektro\\\/ohmmeter-paralel\\\/\",\"name\":\"Ohmmeter Paralel - TN Elektro\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/elektro\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/elektro\\\/ohmmeter-paralel\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/elektro\\\/ohmmeter-paralel\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.tneutron.net\\\/elektro\\\/wp-content\\\/uploads\\\/sites\\\/2\\\/2016\\\/04\\\/image_thumb-20.png\",\"datePublished\":\"2024-06-27T18:30:32+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/elektro\\\/#\\\/schema\\\/person\\\/b57f791b694136047454bb6ac5cbe375\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/elektro\\\/ohmmeter-paralel\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.tneutron.net\\\/elektro\\\/ohmmeter-paralel\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/elektro\\\/ohmmeter-paralel\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.tneutron.net\\\/elektro\\\/wp-content\\\/uploads\\\/sites\\\/2\\\/2016\\\/04\\\/image_thumb-20.png\",\"contentUrl\":\"https:\\\/\\\/www.tneutron.net\\\/elektro\\\/wp-content\\\/uploads\\\/sites\\\/2\\\/2016\\\/04\\\/image_thumb-20.png\",\"width\":244,\"height\":174},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/elektro\\\/ohmmeter-paralel\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.tneutron.net\\\/elektro\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Ohmmeter Paralel\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/elektro\\\/#website\",\"url\":\"https:\\\/\\\/www.tneutron.net\\\/elektro\\\/\",\"name\":\"TN Elektro\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.tneutron.net\\\/elektro\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/elektro\\\/#\\\/schema\\\/person\\\/b57f791b694136047454bb6ac5cbe375\",\"name\":\"Taufiqullah\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/dcdf36434717ce57bea7f17eb3c140a2ff8def45941b720aa8fc1cccd6cdd505?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/dcdf36434717ce57bea7f17eb3c140a2ff8def45941b720aa8fc1cccd6cdd505?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/dcdf36434717ce57bea7f17eb3c140a2ff8def45941b720aa8fc1cccd6cdd505?s=96&d=mm&r=g\",\"caption\":\"Taufiqullah\"},\"description\":\"Taufiqullah\",\"sameAs\":[\"http:\\\/\\\/www.tneutron.net\",\"https:\\\/\\\/x.com\\\/t_neutron\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Ohmmeter Paralel - TN Elektro","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.tneutron.net\/elektro\/ohmmeter-paralel\/","twitter_card":"summary_large_image","twitter_title":"Ohmmeter Paralel - TN Elektro","twitter_description":"Dalam keadaan tidak dipergunakan, saklar S harus dibuka agar batere V tidak lekas menjadi lemah. Bila ohmmeter dipergunakan, maka saklar S ditutup.Mula-mula diambil RX = tak terhingga atau A-B dalam keadaan terbuka, sehingga diperoleh arus melalui M + IM. Pada keadaan ini pontensiometer R2 diatur agar arus melalui M mencapai harga maksimum (skala penuh), sehingga: ...","twitter_image":"https:\/\/www.tneutron.net\/elektro\/wp-content\/uploads\/sites\/2\/2016\/04\/image_thumb-20.png","twitter_creator":"@t_neutron","twitter_misc":{"Written by":"Taufiqullah","Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.tneutron.net\/elektro\/ohmmeter-paralel\/#article","isPartOf":{"@id":"https:\/\/www.tneutron.net\/elektro\/ohmmeter-paralel\/"},"author":{"name":"Taufiqullah","@id":"https:\/\/www.tneutron.net\/elektro\/#\/schema\/person\/b57f791b694136047454bb6ac5cbe375"},"headline":"Ohmmeter Paralel","datePublished":"2024-06-27T18:30:32+00:00","mainEntityOfPage":{"@id":"https:\/\/www.tneutron.net\/elektro\/ohmmeter-paralel\/"},"wordCount":153,"image":{"@id":"https:\/\/www.tneutron.net\/elektro\/ohmmeter-paralel\/#primaryimage"},"thumbnailUrl":"https:\/\/www.tneutron.net\/elektro\/wp-content\/uploads\/sites\/2\/2016\/04\/image_thumb-20.png","keywords":["Ohmmeter Kalibrasi","Ohmmeter Paralel","ohmmeter tipe paralel"],"articleSection":["Pengukuran Resistan Listrik"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.tneutron.net\/elektro\/ohmmeter-paralel\/","url":"https:\/\/www.tneutron.net\/elektro\/ohmmeter-paralel\/","name":"Ohmmeter Paralel - TN Elektro","isPartOf":{"@id":"https:\/\/www.tneutron.net\/elektro\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.tneutron.net\/elektro\/ohmmeter-paralel\/#primaryimage"},"image":{"@id":"https:\/\/www.tneutron.net\/elektro\/ohmmeter-paralel\/#primaryimage"},"thumbnailUrl":"https:\/\/www.tneutron.net\/elektro\/wp-content\/uploads\/sites\/2\/2016\/04\/image_thumb-20.png","datePublished":"2024-06-27T18:30:32+00:00","author":{"@id":"https:\/\/www.tneutron.net\/elektro\/#\/schema\/person\/b57f791b694136047454bb6ac5cbe375"},"breadcrumb":{"@id":"https:\/\/www.tneutron.net\/elektro\/ohmmeter-paralel\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.tneutron.net\/elektro\/ohmmeter-paralel\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.tneutron.net\/elektro\/ohmmeter-paralel\/#primaryimage","url":"https:\/\/www.tneutron.net\/elektro\/wp-content\/uploads\/sites\/2\/2016\/04\/image_thumb-20.png","contentUrl":"https:\/\/www.tneutron.net\/elektro\/wp-content\/uploads\/sites\/2\/2016\/04\/image_thumb-20.png","width":244,"height":174},{"@type":"BreadcrumbList","@id":"https:\/\/www.tneutron.net\/elektro\/ohmmeter-paralel\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.tneutron.net\/elektro\/"},{"@type":"ListItem","position":2,"name":"Ohmmeter Paralel"}]},{"@type":"WebSite","@id":"https:\/\/www.tneutron.net\/elektro\/#website","url":"https:\/\/www.tneutron.net\/elektro\/","name":"TN Elektro","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.tneutron.net\/elektro\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/www.tneutron.net\/elektro\/#\/schema\/person\/b57f791b694136047454bb6ac5cbe375","name":"Taufiqullah","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/dcdf36434717ce57bea7f17eb3c140a2ff8def45941b720aa8fc1cccd6cdd505?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/dcdf36434717ce57bea7f17eb3c140a2ff8def45941b720aa8fc1cccd6cdd505?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/dcdf36434717ce57bea7f17eb3c140a2ff8def45941b720aa8fc1cccd6cdd505?s=96&d=mm&r=g","caption":"Taufiqullah"},"description":"Taufiqullah","sameAs":["http:\/\/www.tneutron.net","https:\/\/x.com\/t_neutron"]}]}},"_links":{"self":[{"href":"https:\/\/www.tneutron.net\/elektro\/wp-json\/wp\/v2\/posts\/1394","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.tneutron.net\/elektro\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.tneutron.net\/elektro\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.tneutron.net\/elektro\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.tneutron.net\/elektro\/wp-json\/wp\/v2\/comments?post=1394"}],"version-history":[{"count":1,"href":"https:\/\/www.tneutron.net\/elektro\/wp-json\/wp\/v2\/posts\/1394\/revisions"}],"predecessor-version":[{"id":5188,"href":"https:\/\/www.tneutron.net\/elektro\/wp-json\/wp\/v2\/posts\/1394\/revisions\/5188"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.tneutron.net\/elektro\/wp-json\/wp\/v2\/media\/1393"}],"wp:attachment":[{"href":"https:\/\/www.tneutron.net\/elektro\/wp-json\/wp\/v2\/media?parent=1394"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.tneutron.net\/elektro\/wp-json\/wp\/v2\/categories?post=1394"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.tneutron.net\/elektro\/wp-json\/wp\/v2\/tags?post=1394"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}