{"id":1975,"date":"2023-12-10T05:00:45","date_gmt":"2023-12-09T22:00:45","guid":{"rendered":"https:\/\/www.tneutron.net\/industri\/?p=1975"},"modified":"2023-12-08T19:14:52","modified_gmt":"2023-12-08T12:14:52","slug":"optical-digital-displacement-transducer","status":"publish","type":"post","link":"https:\/\/www.tneutron.net\/industri\/optical-digital-displacement-transducer\/","title":{"rendered":"Optical Digital Displacement Transducer"},"content":{"rendered":"<p><span class=\"notranslate\">&#8211; detect position through code by reflector or by passing light transmission to photo detector<\/span> <b><\/b><br \/>\n<span class=\"notranslate\"> &#8211; displacement (relative) is measured in the form of a pulse train with a frequency equal to the speed of movement<\/span> <b><\/b><br \/>\n<a href=\"https:\/\/www.tneutron.net\/industri\/wp-content\/uploads\/sites\/3\/2017\/09\/image-1.png\"><img loading=\"lazy\" decoding=\"async\" title=\"image\" src=\"https:\/\/www.tneutron.net\/industri\/wp-content\/uploads\/sites\/3\/2017\/09\/image_thumb-1.png\" alt=\"image\" width=\"491\" height=\"164\" border=\"0\" \/><\/a><br \/>\n<span class=\"notranslate\"> Figure 3.33 Optical digital position sensor: (a) and (b) rotary shift, TX-RX parallel, (c) and (d) horizontal shift, TX-RX forming angle.<\/span><\/p>\n<p><span class=\"notranslate\"> &#8211; motion detection utilizes two signals with different pulse times<\/span><br \/>\n<a href=\"https:\/\/www.tneutron.net\/industri\/wp-content\/uploads\/sites\/3\/2017\/09\/clip_image007-1.jpg\"><img loading=\"lazy\" decoding=\"async\" title=\"clip_image007\" src=\"https:\/\/www.tneutron.net\/industri\/wp-content\/uploads\/sites\/3\/2017\/09\/clip_image007_thumb-1.jpg\" alt=\"clip_image007\" width=\"367\" height=\"265\" border=\"0\" \/><\/a><br \/>\n<span class=\"notranslate\"> Figure 3.34 Rangakain test to determine the direction of movement \/ position<\/span><\/p>\n<p><span class=\"notranslate\"> &#8211; absolute position detected using digital number code<\/span><br \/>\n<span class=\"notranslate\"> \u2022 for extreme change detection one code is used as a clock signal<\/span><br \/>\n<span class=\"notranslate\"> \u2022 other alternatives use code that allows only one change as in Gray code<\/span><br \/>\n<span class=\"notranslate\"> \u2022 Angular code is better than linear code due to the direction of thermal expansion on the code plate<\/span><br \/>\n<a href=\"https:\/\/www.tneutron.net\/industri\/wp-content\/uploads\/sites\/3\/2017\/09\/clip_image011.jpg\"><img loading=\"lazy\" decoding=\"async\" title=\"clip_image011\" src=\"https:\/\/www.tneutron.net\/industri\/wp-content\/uploads\/sites\/3\/2017\/09\/clip_image011_thumb.jpg\" alt=\"clip_image011\" width=\"407\" height=\"158\" border=\"0\" \/><\/a><br \/>\n<span class=\"notranslate\"> Figure 3.35 The clock pulses generated based on binary numbers<\/span><\/p>\n<p><span class=\"notranslate\"> &#8211; small position displacement measurements can be done with Moire pattern<\/span><br \/>\n<span class=\"notranslate\"> \u2022 the upright and oblique pattern strengthens the (size) shift x direction to the line pattern in the y direction<\/span><br \/>\n<span class=\"notranslate\"> \u2022 changes are read optically<\/span><br \/>\n<a href=\"https:\/\/www.tneutron.net\/industri\/wp-content\/uploads\/sites\/3\/2017\/09\/clip_image012.jpg\"><img loading=\"lazy\" decoding=\"async\" title=\"clip_image012\" src=\"https:\/\/www.tneutron.net\/industri\/wp-content\/uploads\/sites\/3\/2017\/09\/clip_image012_thumb.jpg\" alt=\"clip_image012\" width=\"372\" height=\"128\" border=\"0\" \/><\/a><br \/>\n<span class=\"notranslate\"> Figure 3.36 Small position changes using Moire mode<\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>&#8211; detect position through code by reflector or by passing light transmission to photo detector &#8211; displacement (relative) is measured<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"colormag_page_container_layout":"default_layout","colormag_page_sidebar_layout":"default_layout","footnotes":""},"categories":[1830],"tags":[3567,3568,3569,3570,3571,3572,3573,3574,3575,3576,3577,3578,3579,3580,3581,3582],"class_list":["post-1975","post","type-post","status-publish","format-standard","hentry","category-english","tag-electro-optical-transducer","tag-explain-optical-transducer","tag-magneto-optical-current-transducer","tag-magneto-optical-current-transducer-abstract","tag-magneto-optical-current-transducer-images","tag-magneto-optical-current-transducer-pdf","tag-magneto-optical-current-transducer-ppt","tag-nano-optical-transducer","tag-optical-coherence-tomography-transducer","tag-optical-current-transducer","tag-optical-current-transducer-its-fault-location-in-substation","tag-optical-current-transducer-used-in-high-voltage-power-system","tag-optical-encoder-transducer","tag-optical-fiber-current-transducer","tag-optical-grating-transducer","tag-optical-linear-transducer"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Optical Digital Displacement Transducer - TN Industri<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.tneutron.net\/industri\/optical-digital-displacement-transducer\/\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:title\" content=\"Optical Digital Displacement Transducer - TN Industri\" \/>\n<meta name=\"twitter:description\" content=\"&#8211; detect position through code by reflector or by passing light transmission to photo detector &#8211; displacement (relative) is measured\" \/>\n<meta name=\"twitter:image\" content=\"https:\/\/www.tneutron.net\/industri\/wp-content\/uploads\/sites\/3\/2017\/09\/image_thumb-1.png\" \/>\n<meta name=\"twitter:creator\" content=\"@t_neutron\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Taufiqullah\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/industri\\\/optical-digital-displacement-transducer\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/industri\\\/optical-digital-displacement-transducer\\\/\"},\"author\":{\"name\":\"Taufiqullah\",\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/industri\\\/#\\\/schema\\\/person\\\/b57f791b694136047454bb6ac5cbe375\"},\"headline\":\"Optical Digital Displacement Transducer\",\"datePublished\":\"2023-12-09T22:00:45+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/industri\\\/optical-digital-displacement-transducer\\\/\"},\"wordCount\":181,\"image\":{\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/industri\\\/optical-digital-displacement-transducer\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.tneutron.net\\\/industri\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2017\\\/09\\\/image_thumb-1.png\",\"keywords\":[\"electro optical transducer\",\"explain optical transducer\",\"magneto optical current transducer\",\"magneto optical current transducer abstract\",\"magneto optical current transducer images\",\"magneto optical current transducer pdf\",\"magneto optical current transducer ppt\",\"nano optical transducer\",\"optical coherence tomography transducer\",\"optical current transducer\",\"optical current transducer &amp; its fault location in substation\",\"optical current transducer used in high voltage power system\",\"optical encoder transducer\",\"optical fiber current transducer\",\"optical grating transducer\",\"optical linear transducer\"],\"articleSection\":[\"English\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/industri\\\/optical-digital-displacement-transducer\\\/\",\"url\":\"https:\\\/\\\/www.tneutron.net\\\/industri\\\/optical-digital-displacement-transducer\\\/\",\"name\":\"Optical Digital Displacement Transducer - TN Industri\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/industri\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/industri\\\/optical-digital-displacement-transducer\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/industri\\\/optical-digital-displacement-transducer\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.tneutron.net\\\/industri\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2017\\\/09\\\/image_thumb-1.png\",\"datePublished\":\"2023-12-09T22:00:45+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/industri\\\/#\\\/schema\\\/person\\\/b57f791b694136047454bb6ac5cbe375\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/industri\\\/optical-digital-displacement-transducer\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.tneutron.net\\\/industri\\\/optical-digital-displacement-transducer\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/industri\\\/optical-digital-displacement-transducer\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.tneutron.net\\\/industri\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2017\\\/09\\\/image_thumb-1.png\",\"contentUrl\":\"https:\\\/\\\/www.tneutron.net\\\/industri\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2017\\\/09\\\/image_thumb-1.png\",\"width\":491,\"height\":164},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/industri\\\/optical-digital-displacement-transducer\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.tneutron.net\\\/industri\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Optical Digital Displacement Transducer\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/industri\\\/#website\",\"url\":\"https:\\\/\\\/www.tneutron.net\\\/industri\\\/\",\"name\":\"TN Industri\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.tneutron.net\\\/industri\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/industri\\\/#\\\/schema\\\/person\\\/b57f791b694136047454bb6ac5cbe375\",\"name\":\"Taufiqullah\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/dcdf36434717ce57bea7f17eb3c140a2ff8def45941b720aa8fc1cccd6cdd505?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/dcdf36434717ce57bea7f17eb3c140a2ff8def45941b720aa8fc1cccd6cdd505?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/dcdf36434717ce57bea7f17eb3c140a2ff8def45941b720aa8fc1cccd6cdd505?s=96&d=mm&r=g\",\"caption\":\"Taufiqullah\"},\"description\":\"Taufiqullah\",\"sameAs\":[\"http:\\\/\\\/www.tneutron.net\",\"https:\\\/\\\/x.com\\\/t_neutron\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Optical Digital Displacement Transducer - TN Industri","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.tneutron.net\/industri\/optical-digital-displacement-transducer\/","twitter_card":"summary_large_image","twitter_title":"Optical Digital Displacement Transducer - TN Industri","twitter_description":"&#8211; detect position through code by reflector or by passing light transmission to photo detector &#8211; displacement (relative) is measured","twitter_image":"https:\/\/www.tneutron.net\/industri\/wp-content\/uploads\/sites\/3\/2017\/09\/image_thumb-1.png","twitter_creator":"@t_neutron","twitter_misc":{"Written by":"Taufiqullah","Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.tneutron.net\/industri\/optical-digital-displacement-transducer\/#article","isPartOf":{"@id":"https:\/\/www.tneutron.net\/industri\/optical-digital-displacement-transducer\/"},"author":{"name":"Taufiqullah","@id":"https:\/\/www.tneutron.net\/industri\/#\/schema\/person\/b57f791b694136047454bb6ac5cbe375"},"headline":"Optical Digital Displacement Transducer","datePublished":"2023-12-09T22:00:45+00:00","mainEntityOfPage":{"@id":"https:\/\/www.tneutron.net\/industri\/optical-digital-displacement-transducer\/"},"wordCount":181,"image":{"@id":"https:\/\/www.tneutron.net\/industri\/optical-digital-displacement-transducer\/#primaryimage"},"thumbnailUrl":"https:\/\/www.tneutron.net\/industri\/wp-content\/uploads\/sites\/3\/2017\/09\/image_thumb-1.png","keywords":["electro optical transducer","explain optical transducer","magneto optical current transducer","magneto optical current transducer abstract","magneto optical current transducer images","magneto optical current transducer pdf","magneto optical current transducer ppt","nano optical transducer","optical coherence tomography transducer","optical current transducer","optical current transducer &amp; its fault location in substation","optical current transducer used in high voltage power system","optical encoder transducer","optical fiber current transducer","optical grating transducer","optical linear transducer"],"articleSection":["English"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.tneutron.net\/industri\/optical-digital-displacement-transducer\/","url":"https:\/\/www.tneutron.net\/industri\/optical-digital-displacement-transducer\/","name":"Optical Digital Displacement Transducer - TN Industri","isPartOf":{"@id":"https:\/\/www.tneutron.net\/industri\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.tneutron.net\/industri\/optical-digital-displacement-transducer\/#primaryimage"},"image":{"@id":"https:\/\/www.tneutron.net\/industri\/optical-digital-displacement-transducer\/#primaryimage"},"thumbnailUrl":"https:\/\/www.tneutron.net\/industri\/wp-content\/uploads\/sites\/3\/2017\/09\/image_thumb-1.png","datePublished":"2023-12-09T22:00:45+00:00","author":{"@id":"https:\/\/www.tneutron.net\/industri\/#\/schema\/person\/b57f791b694136047454bb6ac5cbe375"},"breadcrumb":{"@id":"https:\/\/www.tneutron.net\/industri\/optical-digital-displacement-transducer\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.tneutron.net\/industri\/optical-digital-displacement-transducer\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.tneutron.net\/industri\/optical-digital-displacement-transducer\/#primaryimage","url":"https:\/\/www.tneutron.net\/industri\/wp-content\/uploads\/sites\/3\/2017\/09\/image_thumb-1.png","contentUrl":"https:\/\/www.tneutron.net\/industri\/wp-content\/uploads\/sites\/3\/2017\/09\/image_thumb-1.png","width":491,"height":164},{"@type":"BreadcrumbList","@id":"https:\/\/www.tneutron.net\/industri\/optical-digital-displacement-transducer\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.tneutron.net\/industri\/"},{"@type":"ListItem","position":2,"name":"Optical Digital Displacement Transducer"}]},{"@type":"WebSite","@id":"https:\/\/www.tneutron.net\/industri\/#website","url":"https:\/\/www.tneutron.net\/industri\/","name":"TN Industri","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.tneutron.net\/industri\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/www.tneutron.net\/industri\/#\/schema\/person\/b57f791b694136047454bb6ac5cbe375","name":"Taufiqullah","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/dcdf36434717ce57bea7f17eb3c140a2ff8def45941b720aa8fc1cccd6cdd505?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/dcdf36434717ce57bea7f17eb3c140a2ff8def45941b720aa8fc1cccd6cdd505?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/dcdf36434717ce57bea7f17eb3c140a2ff8def45941b720aa8fc1cccd6cdd505?s=96&d=mm&r=g","caption":"Taufiqullah"},"description":"Taufiqullah","sameAs":["http:\/\/www.tneutron.net","https:\/\/x.com\/t_neutron"]}]}},"_links":{"self":[{"href":"https:\/\/www.tneutron.net\/industri\/wp-json\/wp\/v2\/posts\/1975","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.tneutron.net\/industri\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.tneutron.net\/industri\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.tneutron.net\/industri\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.tneutron.net\/industri\/wp-json\/wp\/v2\/comments?post=1975"}],"version-history":[{"count":1,"href":"https:\/\/www.tneutron.net\/industri\/wp-json\/wp\/v2\/posts\/1975\/revisions"}],"predecessor-version":[{"id":3513,"href":"https:\/\/www.tneutron.net\/industri\/wp-json\/wp\/v2\/posts\/1975\/revisions\/3513"}],"wp:attachment":[{"href":"https:\/\/www.tneutron.net\/industri\/wp-json\/wp\/v2\/media?parent=1975"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.tneutron.net\/industri\/wp-json\/wp\/v2\/categories?post=1975"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.tneutron.net\/industri\/wp-json\/wp\/v2\/tags?post=1975"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}