{"id":523,"date":"2024-06-04T05:40:35","date_gmt":"2024-06-03T22:40:35","guid":{"rendered":"http:\/\/www.tneutron.net\/industri\/?p=523"},"modified":"2024-05-31T07:52:28","modified_gmt":"2024-05-31T00:52:28","slug":"usage-control-system","status":"publish","type":"post","link":"https:\/\/www.tneutron.net\/industri\/usage-control-system\/","title":{"rendered":"Usage Control System"},"content":{"rendered":"<p><span class=\"notranslate\"><strong>1 Speed \u200b\u200bControl System<\/strong><\/span> <strong><br \/>\n<\/strong> <span class=\"notranslate\"> Governor Watt basic principle of Watt&#8217;s governor engine with the schematic diagram illustrated in Figure 9.8.<\/span> <span class=\"notranslate\"> The magnitude of the rate of flow of fuel into the engine cylinders arranged in accordance with the difference between desired engine speed and actual engine speeds.<\/span> <span class=\"notranslate\"> Governor speed set according to the desired speed.<\/span> <span class=\"notranslate\"> The actual speed drops below the desired price, the centrifugal force speed governor is becoming increasingly smaller, causing the control valve to move downward, distribute the fuel more so the enlarged engine speed to achieve the desired price.<\/span><\/p>\n<p><span class=\"notranslate\"> Conversely, if the engine speed exceeds the desired value, then the centrifugal force of the speed governor is getting bigger, it causes the control valve to move upward.<\/span> <span class=\"notranslate\"> This will reduce the supply of fuel to the engine speed mengecilsampai achieved the desired value.<\/span><\/p>\n<p><span class=\"notranslate\"> At this speed control systems, plant (controlled system) is the engine and the controlled variable is the speed of the machine.<\/span> <span class=\"notranslate\"> The difference between the desired speed and the actual speed is a signal, error.<\/span> <span class=\"notranslate\"> A control signal (amount of fuel) to be applied to the plant (engine) is the actuation signal.<\/span> <span class=\"notranslate\"> External input variables that will interfere yangdikontrol is a nuisance.<\/span> <span class=\"notranslate\"> Load change is not expected is a nuisance.<\/span><\/p>\n<p><span class=\"notranslate\"> <strong>2 Temperature Control System<\/strong><\/span><\/p>\n<p><a href=\"http:\/\/i1.wp.com\/www.tneutron.net\/industri\/wp-content\/uploads\/sites\/3\/2015\/09\/image6.png\"><img loading=\"lazy\" decoding=\"async\" title=\"image\" src=\"http:\/\/i2.wp.com\/www.tneutron.net\/industri\/wp-content\/uploads\/sites\/3\/2015\/09\/image_thumb7.png?resize=375%2C136\" alt=\"image\" width=\"375\" height=\"136\" border=\"0\" \/><\/a><\/p>\n<p><span class=\"notranslate\"> Figure 2.8 Temperature Control System car<\/span><\/p>\n<p><span class=\"notranslate\">Figure 2.8 shows a diagram of the temperature control electric stove.<\/span> <span class=\"notranslate\"> The temperature is measured by a temperature sensor (the components that generate analog signals).<\/span> <span class=\"notranslate\"> The magnitude of temperature stress in the form of analog signals are converted into digital quantities by the converter A \/ D.<\/span> <span class=\"notranslate\"> Digital temperature controller is inserted through an interface.<\/span> <span class=\"notranslate\"> Digital temperature is compared with the temperature input is programmed, and if there is a deviation (error), the controller sends a signal to the heater through an amplifier and a relay interface, to bring the temperature of the stove to the desired value.<\/span><\/p>\n<p><a href=\"http:\/\/i0.wp.com\/www.tneutron.net\/industri\/wp-content\/uploads\/sites\/3\/2015\/09\/image11.png\"><img loading=\"lazy\" decoding=\"async\" title=\"image\" src=\"http:\/\/i0.wp.com\/www.tneutron.net\/industri\/wp-content\/uploads\/sites\/3\/2015\/09\/image_thumb11.png?resize=336%2C226\" alt=\"image\" width=\"336\" height=\"226\" border=\"0\" \/><\/a><\/p>\n<p><span class=\"notranslate\"> Figure 2.9 The function of temperature control of passenger space<\/span><\/p>\n<p><span class=\"notranslate\"><strong>3 Room Temperature Control System Passenger Cars<\/strong><\/span> <strong><br \/>\n<\/strong> <span class=\"notranslate\"> Figure 2.9 shows the control function of the temperature of the passenger car.<\/span> <span class=\"notranslate\"> Desired temperature, is converted into a voltage, is input to the controller.<\/span> <span class=\"notranslate\"> The actual temperature of the passenger space is converted to a voltage through a sensor \/ transducer and fed back to the controller for comparison with the input.<\/span> <span class=\"notranslate\"> Room temperature and radiation heat transfer from the sun, act as a distraction.<\/span> <span class=\"notranslate\"> The system uses a feedback control maupunkontrol good feedback to the front.<\/span><\/p>\n<p><span class=\"notranslate\"> (Feed forward control gives aksikoreksi before the disturbance affects the output).<\/span> <span class=\"notranslate\"> The temperature of the passenger car differs quite large depending on where it is measured.<\/span> <span class=\"notranslate\"> Instead of using many sensors for temperature measurement and leveling the measured value, it is more economical to install the vacuum or blower in a place where passengers usually feel the temperature.<\/span> <span class=\"notranslate\"> Temperatures of the vacuum or blower is a clue passenger room temperature (output system).<\/span><\/p>\n<p><span class=\"notranslate\">The controller receives input signals, output signals and a signal from the sensor noise source.<\/span> <span class=\"notranslate\"> The controller sends a signal to optimally control the air adjusting device (air conditioner) to control the amount of air conditioning such that the passenger space is equal to the desired temperature.<\/span><\/p>\n<p><a href=\"http:\/\/i2.wp.com\/www.tneutron.net\/industri\/wp-content\/uploads\/sites\/3\/2015\/09\/image14.png\"><img loading=\"lazy\" decoding=\"async\" title=\"image\" src=\"http:\/\/i2.wp.com\/www.tneutron.net\/industri\/wp-content\/uploads\/sites\/3\/2015\/09\/image_thumb14.png?resize=330%2C204\" alt=\"image\" width=\"330\" height=\"204\" border=\"0\" \/><\/a><\/p>\n<p><span class=\"notranslate\"> Figure 2.10 Temperature Control System in Space Passenger Cars<\/span><\/p>\n<p><span class=\"notranslate\"> <strong>4 Traffic Control System<\/strong><\/span> <strong><br \/>\n<\/strong> <span class=\"notranslate\"> Controlling traffic with traffic signals operated on the basis of time to form an open loop control system.<\/span> <span class=\"notranslate\"> However, if the number of cars waiting at each traffic signal in an area that is crowded at all, in a city, is measured continuously and the information is sent to the central computer that controls traffic signals, then such a system becomes a closed loop.<\/span><\/p>\n<p><span class=\"notranslate\">The movement of traffic in the network is quite complex because of the variation of the volume of traffic is very dependent on the hour and day of the week, as well as on several other factors.<\/span> <span class=\"notranslate\"> In some cases, the Poisson distribution can be applied to the arrival at the crossroads, but it need not be true for semuapersoalan traffic.<\/span> <span class=\"notranslate\"> In fact, to minimize the average waiting time is a very complex control problems.<\/span><\/p>\n<p><span class=\"notranslate\"> <strong>5 Inventory Control Systems and Business Systems<\/strong><\/span> <strong><br \/>\n<\/strong> <span class=\"notranslate\"> Programming the rate of production and inventory levels in the industry is another example of a closed loop control system.<\/span> <span class=\"notranslate\"> Actual inventory levels, which is the output of the system, compared with the desired inventory levels, which may change from time to time in accordance with the market.<\/span> <span class=\"notranslate\"> If there is a difference between actual inventory levels with inventory levels is desired, then the production rate adjusted such that the output is always approaching the &#8220;level&#8221; is desired, which is chosen to maximize profits.<\/span><\/p>\n<p><span class=\"notranslate\"> Business system can consist of several groups, each of which has the task (dynamic elements of the system).<\/span> <span class=\"notranslate\"> Feedback method to report on the achievements of each group should be set in such a system, in order to operate properly.<\/span> <span class=\"notranslate\"> Cross coupling between the functional groups must be made in order minimum, to reduce the time delay is not desirable in the system.<\/span> <span class=\"notranslate\"> The smaller the cross coupling more it will smooth signal flow of work and materials.<\/span><\/p>\n<p><a href=\"http:\/\/i1.wp.com\/www.tneutron.net\/industri\/wp-content\/uploads\/sites\/3\/2015\/09\/image16.png\"><img loading=\"lazy\" decoding=\"async\" title=\"image\" src=\"http:\/\/i0.wp.com\/www.tneutron.net\/industri\/wp-content\/uploads\/sites\/3\/2015\/09\/image_thumb16.png?resize=333%2C171\" alt=\"image\" width=\"333\" height=\"171\" border=\"0\" \/><\/a><\/p>\n<p><span class=\"notranslate\"> Figure 2.11 Steering and Control System Idle Speed \u200b\u200bat the Mobil<\/span><\/p>\n<p><span class=\"notranslate\">Business system is a closed loop system.<\/span> <span class=\"notranslate\"> Good design will simplify the necessary managerial control.<\/span> <span class=\"notranslate\"> Note that disruption in this system is defective in materials or human, communication interruption, human error, and the like.<\/span><\/p>\n<p><a href=\"http:\/\/i2.wp.com\/www.tneutron.net\/industri\/wp-content\/uploads\/sites\/3\/2015\/09\/image17.png\"><img loading=\"lazy\" decoding=\"async\" title=\"image\" src=\"http:\/\/i2.wp.com\/www.tneutron.net\/industri\/wp-content\/uploads\/sites\/3\/2015\/09\/image_thumb17.png?resize=444%2C47\" alt=\"image\" width=\"444\" height=\"47\" border=\"0\" \/><\/a><\/p>\n<p><span class=\"notranslate\"> Figure 2.12 Idle Speed \u200b\u200bSystem with Open Loop<\/span><\/p>\n<p><span class=\"notranslate\"> A good estimate determination system is based on statistics and power management.<\/span> <span class=\"notranslate\"> (Note that it is known from the fact that the system performance can be improved by setting the time or anticipation).<\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>1 Speed \u200b\u200bControl System Governor Watt basic principle of Watt&#8217;s governor engine with the schematic diagram illustrated in Figure 9.8.<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"colormag_page_container_layout":"default_layout","colormag_page_sidebar_layout":"default_layout","footnotes":""},"categories":[1830],"tags":[672,669,670,671],"class_list":["post-523","post","type-post","status-publish","format-standard","hentry","category-english","tag-usage-control-in-cloud-systems","tag-usage-control-system","tag-usage-of-control-systems","tag-water-usage-control-system"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Usage Control System - TN Industri<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.tneutron.net\/industri\/usage-control-system\/\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:title\" content=\"Usage Control System - TN Industri\" \/>\n<meta name=\"twitter:description\" content=\"1 Speed \u200b\u200bControl System Governor Watt basic principle of Watt&#8217;s governor engine with the schematic diagram illustrated in Figure 9.8.\" \/>\n<meta name=\"twitter:image\" content=\"http:\/\/i2.wp.com\/www.tneutron.net\/industri\/wp-content\/uploads\/sites\/3\/2015\/09\/image_thumb7.png?resize=375%2C136\" \/>\n<meta name=\"twitter:creator\" content=\"@t_neutron\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Taufiqullah\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/industri\\\/usage-control-system\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/industri\\\/usage-control-system\\\/\"},\"author\":{\"name\":\"Taufiqullah\",\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/industri\\\/#\\\/schema\\\/person\\\/b57f791b694136047454bb6ac5cbe375\"},\"headline\":\"Usage Control System\",\"datePublished\":\"2024-06-03T22:40:35+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/industri\\\/usage-control-system\\\/\"},\"wordCount\":925,\"image\":{\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/industri\\\/usage-control-system\\\/#primaryimage\"},\"thumbnailUrl\":\"http:\\\/\\\/i2.wp.com\\\/www.tneutron.net\\\/industri\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2015\\\/09\\\/image_thumb7.png?resize=375%2C136\",\"keywords\":[\"usage control in cloud systems\",\"Usage Control System\",\"usage of control systems\",\"water usage control system\"],\"articleSection\":[\"English\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/industri\\\/usage-control-system\\\/\",\"url\":\"https:\\\/\\\/www.tneutron.net\\\/industri\\\/usage-control-system\\\/\",\"name\":\"Usage Control System - TN Industri\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/industri\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/industri\\\/usage-control-system\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/industri\\\/usage-control-system\\\/#primaryimage\"},\"thumbnailUrl\":\"http:\\\/\\\/i2.wp.com\\\/www.tneutron.net\\\/industri\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2015\\\/09\\\/image_thumb7.png?resize=375%2C136\",\"datePublished\":\"2024-06-03T22:40:35+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/industri\\\/#\\\/schema\\\/person\\\/b57f791b694136047454bb6ac5cbe375\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/industri\\\/usage-control-system\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.tneutron.net\\\/industri\\\/usage-control-system\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/industri\\\/usage-control-system\\\/#primaryimage\",\"url\":\"http:\\\/\\\/i2.wp.com\\\/www.tneutron.net\\\/industri\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2015\\\/09\\\/image_thumb7.png?resize=375%2C136\",\"contentUrl\":\"http:\\\/\\\/i2.wp.com\\\/www.tneutron.net\\\/industri\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2015\\\/09\\\/image_thumb7.png?resize=375%2C136\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/industri\\\/usage-control-system\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.tneutron.net\\\/industri\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Usage Control System\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/industri\\\/#website\",\"url\":\"https:\\\/\\\/www.tneutron.net\\\/industri\\\/\",\"name\":\"TN Industri\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.tneutron.net\\\/industri\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.tneutron.net\\\/industri\\\/#\\\/schema\\\/person\\\/b57f791b694136047454bb6ac5cbe375\",\"name\":\"Taufiqullah\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/dcdf36434717ce57bea7f17eb3c140a2ff8def45941b720aa8fc1cccd6cdd505?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/dcdf36434717ce57bea7f17eb3c140a2ff8def45941b720aa8fc1cccd6cdd505?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/dcdf36434717ce57bea7f17eb3c140a2ff8def45941b720aa8fc1cccd6cdd505?s=96&d=mm&r=g\",\"caption\":\"Taufiqullah\"},\"description\":\"Taufiqullah\",\"sameAs\":[\"http:\\\/\\\/www.tneutron.net\",\"https:\\\/\\\/x.com\\\/t_neutron\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Usage Control System - TN Industri","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.tneutron.net\/industri\/usage-control-system\/","twitter_card":"summary_large_image","twitter_title":"Usage Control System - TN Industri","twitter_description":"1 Speed \u200b\u200bControl System Governor Watt basic principle of Watt&#8217;s governor engine with the schematic diagram illustrated in Figure 9.8.","twitter_image":"http:\/\/i2.wp.com\/www.tneutron.net\/industri\/wp-content\/uploads\/sites\/3\/2015\/09\/image_thumb7.png?resize=375%2C136","twitter_creator":"@t_neutron","twitter_misc":{"Written by":"Taufiqullah","Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.tneutron.net\/industri\/usage-control-system\/#article","isPartOf":{"@id":"https:\/\/www.tneutron.net\/industri\/usage-control-system\/"},"author":{"name":"Taufiqullah","@id":"https:\/\/www.tneutron.net\/industri\/#\/schema\/person\/b57f791b694136047454bb6ac5cbe375"},"headline":"Usage Control System","datePublished":"2024-06-03T22:40:35+00:00","mainEntityOfPage":{"@id":"https:\/\/www.tneutron.net\/industri\/usage-control-system\/"},"wordCount":925,"image":{"@id":"https:\/\/www.tneutron.net\/industri\/usage-control-system\/#primaryimage"},"thumbnailUrl":"http:\/\/i2.wp.com\/www.tneutron.net\/industri\/wp-content\/uploads\/sites\/3\/2015\/09\/image_thumb7.png?resize=375%2C136","keywords":["usage control in cloud systems","Usage Control System","usage of control systems","water usage control system"],"articleSection":["English"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.tneutron.net\/industri\/usage-control-system\/","url":"https:\/\/www.tneutron.net\/industri\/usage-control-system\/","name":"Usage Control System - TN Industri","isPartOf":{"@id":"https:\/\/www.tneutron.net\/industri\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.tneutron.net\/industri\/usage-control-system\/#primaryimage"},"image":{"@id":"https:\/\/www.tneutron.net\/industri\/usage-control-system\/#primaryimage"},"thumbnailUrl":"http:\/\/i2.wp.com\/www.tneutron.net\/industri\/wp-content\/uploads\/sites\/3\/2015\/09\/image_thumb7.png?resize=375%2C136","datePublished":"2024-06-03T22:40:35+00:00","author":{"@id":"https:\/\/www.tneutron.net\/industri\/#\/schema\/person\/b57f791b694136047454bb6ac5cbe375"},"breadcrumb":{"@id":"https:\/\/www.tneutron.net\/industri\/usage-control-system\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.tneutron.net\/industri\/usage-control-system\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.tneutron.net\/industri\/usage-control-system\/#primaryimage","url":"http:\/\/i2.wp.com\/www.tneutron.net\/industri\/wp-content\/uploads\/sites\/3\/2015\/09\/image_thumb7.png?resize=375%2C136","contentUrl":"http:\/\/i2.wp.com\/www.tneutron.net\/industri\/wp-content\/uploads\/sites\/3\/2015\/09\/image_thumb7.png?resize=375%2C136"},{"@type":"BreadcrumbList","@id":"https:\/\/www.tneutron.net\/industri\/usage-control-system\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.tneutron.net\/industri\/"},{"@type":"ListItem","position":2,"name":"Usage Control System"}]},{"@type":"WebSite","@id":"https:\/\/www.tneutron.net\/industri\/#website","url":"https:\/\/www.tneutron.net\/industri\/","name":"TN Industri","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.tneutron.net\/industri\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/www.tneutron.net\/industri\/#\/schema\/person\/b57f791b694136047454bb6ac5cbe375","name":"Taufiqullah","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/dcdf36434717ce57bea7f17eb3c140a2ff8def45941b720aa8fc1cccd6cdd505?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/dcdf36434717ce57bea7f17eb3c140a2ff8def45941b720aa8fc1cccd6cdd505?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/dcdf36434717ce57bea7f17eb3c140a2ff8def45941b720aa8fc1cccd6cdd505?s=96&d=mm&r=g","caption":"Taufiqullah"},"description":"Taufiqullah","sameAs":["http:\/\/www.tneutron.net","https:\/\/x.com\/t_neutron"]}]}},"_links":{"self":[{"href":"https:\/\/www.tneutron.net\/industri\/wp-json\/wp\/v2\/posts\/523","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.tneutron.net\/industri\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.tneutron.net\/industri\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.tneutron.net\/industri\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.tneutron.net\/industri\/wp-json\/wp\/v2\/comments?post=523"}],"version-history":[{"count":1,"href":"https:\/\/www.tneutron.net\/industri\/wp-json\/wp\/v2\/posts\/523\/revisions"}],"predecessor-version":[{"id":3552,"href":"https:\/\/www.tneutron.net\/industri\/wp-json\/wp\/v2\/posts\/523\/revisions\/3552"}],"wp:attachment":[{"href":"https:\/\/www.tneutron.net\/industri\/wp-json\/wp\/v2\/media?parent=523"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.tneutron.net\/industri\/wp-json\/wp\/v2\/categories?post=523"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.tneutron.net\/industri\/wp-json\/wp\/v2\/tags?post=523"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}