Cylinder Bore Gauge before use should be calibrated beforehand using a micrometer Affairs.<\/span><\/p>\n Sample readings Bore Cylinder gauge For example we will mangukur cylinder diameter.<\/span> The first time we measure the diameter with a vernier caliper to determine the diameter is roughly in order to choose the right rod end to be fitted in the bore gauge (or see the standard size on standard maintenance).<\/span> For example obtained size 75 mm vernier caliper, then we choose the rod end prices marked 75 in the middle of the bore gauge standard.<\/span><\/p>\n Because we get the results of the first measurements of 75 mm then we use a micrometer is 75-100 mm.<\/span> Then set the price of a standard micrometer to measure to determine the position of zeros.<\/span> Attach the micrometer on the micrometer stand.<\/span> Attach dial gauge by loosening the nut fastener position dial gauge (dial gauge securing position) until a small needle to move up in numbers one and tighten the nut fastening.<\/span><\/p>\nPair bore micrometer gauge on the rod end and the needle tip on the anvil and the micrometer spindle until the maximum large needle motion clockwise then the position of the rotating outer rim up zeros on the position of the needle.<\/span> If a small needle shows the numbers one and a large needle on a strip that all 22 after moving from zero clockwise, so the measurement results:<\/span><\/p>\n\n- Small needle = 1 test = 75 mm<\/span><\/li>\n
- Large needles = 22 x 0.01 mm = 0.22 mm<\/span><\/li>\n
- Readings = 75 – 0:22 = 74.78 mm<\/span><\/li>\n<\/ul>\n
If a small needle shows the numbers one and a large needle on the strip<\/span>
\n 25th after moving from zero counterclockwise, so the results<\/span>
\n measurements:<\/span><\/p>\n\n- Small needle = 1 test = 75 mm<\/span><\/li>\n
- Large needles = 25 x 0.01 mm = 0.25 mm +<\/span><\/li>\n
- Readings = 75 + 0.25 = 75.25 mm<\/span><\/li>\n<\/ul>\n
To facilitate the reading of the measurement results:<\/span><\/p>\n\n- If the dial gauge needle moves clockwise then the measurement results are reduced or in other words, the measured diameter is smaller than the standard.<\/span> \uf0b7<\/span><\/li>\n
- If the dial gauge needle moves counter-clockwise so the measurement results are added, or in other words, the measured diameter is greater than the standard price.<\/span><\/li>\n<\/ul>\n
For the measurement of the diameter of the cylinder that is not on the size of the rod end should be added to the spacer (shim).<\/span> At each bore gauge are thick spacer: 1 mm;<\/span> 2 mm;<\/span> 3 mm.<\/span> For example size 78 or 83 mm diameter with a vernier caliper.<\/span> For the selection of the bore gauge rod end on the download size of 75 mm or 80 mm spacer and then add 3 mm thick and then set alternately on a micrometer to measure new 78 or 83 mm is used to take measurements.<\/span><\/p>\n","protected":false},"excerpt":{"rendered":"Applications bore gauge is not measuring application inside micrometer, because bore gauge has a long stalk tool holder and a dial gauge to read the measurement results, so in places that can not use the narrow bore gauge, for example, is a bore for camshaft bushing. Cylinder Bore gauge is widely used to measure the …<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1406],"tags":[1503,1506,1512,1505,1511,1509,1504,1507,1508,1510],"class_list":["post-1452","post","type-post","status-publish","format-standard","hentry","category-english","tag-cylinder-gauge","tag-cylinder-gauge-chart","tag-cylinder-gauge-html5","tag-cylinder-gauge-javascript","tag-cylinder-gauge-jquery","tag-cylinder-gauge-manual","tag-cylinder-gauge-mitutoyo","tag-cylinder-gauge-tools","tag-cylinder-gauge-use","tag-cylinder-gauge-wiki"],"_links":{"self":[{"href":"https:\/\/www.tneutron.net\/mesin\/wp-json\/wp\/v2\/posts\/1452","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.tneutron.net\/mesin\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.tneutron.net\/mesin\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.tneutron.net\/mesin\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.tneutron.net\/mesin\/wp-json\/wp\/v2\/comments?post=1452"}],"version-history":[{"count":1,"href":"https:\/\/www.tneutron.net\/mesin\/wp-json\/wp\/v2\/posts\/1452\/revisions"}],"predecessor-version":[{"id":3083,"href":"https:\/\/www.tneutron.net\/mesin\/wp-json\/wp\/v2\/posts\/1452\/revisions\/3083"}],"wp:attachment":[{"href":"https:\/\/www.tneutron.net\/mesin\/wp-json\/wp\/v2\/media?parent=1452"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.tneutron.net\/mesin\/wp-json\/wp\/v2\/categories?post=1452"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.tneutron.net\/mesin\/wp-json\/wp\/v2\/tags?post=1452"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}