Valve in general does not use packing, this is because the leak is small.<\/span> However, because the fluid that flows in the hydraulic system is always followed by some dirt, fibers, rust, etc., then gradually these valve holes will be clogged, scratched or even leaked.<\/span> If this happens, it will cause the fluid pressure to drop (drop).<\/span> For that hydraulic fluid must be really paid attention carefully and the way of operation must be careful.<\/span><\/p>\n How to repair hydraulic valve can be done in the following way:<\/span><\/p>\n When clamping the valve on the viscosity, it should use an aluminum brass protector (base) to avoid injury to the valve being clamped or it may be wrapped with soft materials.<\/span><\/p>\n Valve maintenance<\/b><\/span> Keep the valve in a safe place (cupboard) to avoid dirt (dust) around.<\/span><\/p>\n","protected":false},"excerpt":{"rendered":" Valve in general does not use packing, this is because the leak is small. However, because the fluid that flows in the hydraulic system is always followed by some dirt, fibers, rust, etc., then gradually these valve holes will be clogged, scratched or even leaked. If this happens, it will cause the fluid pressure to …<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1406],"tags":[2506,2507,2508,2509,2510,2511,2512,2513,2514,2515,2516,2517,2518,2519,2520,2521,2522,2523,2524,2525],"class_list":["post-1804","post","type-post","status-publish","format-standard","hentry","category-english","tag-bosch-hydraulic-valve-repair","tag-cross-hydraulic-valves-repair-parts","tag-energy-hydraulic-valve-repair-kit","tag-gresen-hydraulic-control-valve-repair","tag-husco-hydraulic-valve-repair","tag-hydraulic-control-valve-repair","tag-hydraulic-control-valve-repair-kit","tag-hydraulic-elevator-valve-repair","tag-hydraulic-jack-release-valve-repair","tag-hydraulic-relief-valve-repair","tag-hydraulic-spool-valve-repair","tag-hydraulic-valve-bank-repair","tag-hydraulic-valve-block-repair","tag-hydraulic-valve-body-repair","tag-hydraulic-valve-lifter-repair","tag-hydraulic-valve-lifter-repair-cost","tag-hydraulic-valve-lifter-replacement","tag-hydraulic-valve-repair","tag-hydraulic-valve-repair-kits","tag-hydraulic-valve-repair-milwaukee"],"_links":{"self":[{"href":"https:\/\/www.tneutron.net\/mesin\/wp-json\/wp\/v2\/posts\/1804","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.tneutron.net\/mesin\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.tneutron.net\/mesin\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.tneutron.net\/mesin\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.tneutron.net\/mesin\/wp-json\/wp\/v2\/comments?post=1804"}],"version-history":[{"count":1,"href":"https:\/\/www.tneutron.net\/mesin\/wp-json\/wp\/v2\/posts\/1804\/revisions"}],"predecessor-version":[{"id":3012,"href":"https:\/\/www.tneutron.net\/mesin\/wp-json\/wp\/v2\/posts\/1804\/revisions\/3012"}],"wp:attachment":[{"href":"https:\/\/www.tneutron.net\/mesin\/wp-json\/wp\/v2\/media?parent=1804"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.tneutron.net\/mesin\/wp-json\/wp\/v2\/categories?post=1804"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.tneutron.net\/mesin\/wp-json\/wp\/v2\/tags?post=1804"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}\n
\n
\n If the hydraulic pump is absolutely sure there is no problem, then that needs to be considered is the valve, because this valve can reduce the performance of the hydraulic system.<\/span> The way of maintenance is as follows:<\/span>
\n 1. Check the pressure setting on the valve, because if it is too low it will cause the fluid coming from the pump through the valve \/ valve it will be returned to the tank without going to the driving element (Actuator).<\/span>
\n 2. Clean the valve components using a cleaning agent, because if not cleaned then the valve will contain sediment deposits that can jam the movement of the valve.<\/span>
\n 3. After all valve components are installed, try checking the valve position, because it may be wrong to install it for example valve steering position was accidentally opened in the neutral position, then the oil will flow back to the tank without any pressure enough to move the element other.<\/span><\/p>\n