Sample Line Separator
When the sample point (point sampling) are liquid, then the liquid separator placed between the source and the sample container. A sintered metal filter (sintered metal filter) can also be used to maintain the solid particles out of the sample container. For clarity, the sampling gas separator as shown in Figures 2 and 3. Separator is designed in accordance with the pressure vessel code.
![]()
Figure 2. Example of Sampling Gas Separator
![]()
Figure 3. Example of Sampling Gas Separator type B
Sampling Points
Pay attention to the selection of the sampling (sampling points). For gas sampling, sampling points taken at the summit pada- horizontal flow, meant to reduce the occurrence of liquid contamination.
In addition, the sampling points can also be taken in part after bangkok position or after a given obstacle (obstacle), meant to reduce the occurrence of liquid contamination.
Container Sample Preparation
Prior to sampling, sample containers must be cleaned, especially for samples in the form of liquid hydrocarbons. The existence of a layer of oil, grease, or sludge can be cleaned by purging with steam, immediately washed with hot detergent solution or washed with a solvent and then dried.