Synchronous Generator 3 Phase

Electric generators are widely used in power stations is 3 phase synchronous generator. 1. Installation clamps 3 phase synchronous generator Coding on clamps for 3 phase synchronous generator there are A, B, C and N to the relationship of as shown in Figure II.1. Electrical circuit 3 phase synchronous generator is shown in Figure II.2.   Figure II.1 3 phase ...

Read More »

Sinkon 3 Phasa Generator and Rail

1. Protection cable duct between the generator and rail Performed using a cable that is placed on a special channel in the soil and if it is above ground wires placed on shelves buffer that protects the cable mechanically. The mechanical protection to prevent damage to cables and can cause interference. Disorders of the cable between the generator with rail ...

Read More »

Voltage Synchronous Generator 3 Phase

Setting Automatic Voltage 3 phase synchronous generator using Type Electro Mechanical AVR Brown & Cie (AVR – BBC).   Figure II.22 working principle AVR Brown & Cie In hydropower Mendalan automatic voltage settings (AVR) using a type of electro mechanical AVR Brown & Cie. AVR is composed of two sectors barriers equipped P groove contacts form a circle. These contacts ...

Read More »

Mechanism Vacuum PMT

Flexibility metal is one of the obstacles to the development of vacuum PMT because the distance between the contacts to be limited so that the vacuum PMT voltage operation is also limited.   Figure II.46 Construction PMT blackout space S Figure II.48 shows the construction of space in a simple outage SF6 PMT.   Figure II.48 Construction blackout space PMT ...

Read More »

Amplifier System Generator

The main generator amplifier tends to evolve from an alternating current generator connected to a synchronous generator through a rectifier which rotates the generator shaft so it does not need slip rings. Figure II.8 shows elongated pieces bipolar rotor synchronous generator (rotor turbo generator) bipolar and Figure II.9 shows the hydroelectric generator rotor Long City (Riau) pole lot 57 MW. ...

Read More »

Voltage Regulator Generator

When the rotor spins will lead to the intersection between the stator winding field coils resulting electromotive force (GGL). In the process to generate a voltage in the main generator requires strengthening or excitacy. That is using a current transformer (CT = Current Transformer) / PT (Potential Transformer Voltage Transformer =) Automatic Voltage Regulator (AVR) as a conduit for the ...

Read More »