Things to consider in measuring the voltage is switch positions and limit measure measuring range (range). If will measure 220 ACV, switch the measuring range must be in a position ACV, and limit measure (range) at number 250 ACV. The same applies to DC voltage measurement (DCV). Equally important to note is the safety factor. Note whether the cable wrapping ...
Read More »Author Archives: Taufiqullah
Understanding Massa and Enterprises
Massa is the physical properties of an object, which can generally be used to measure the amount of material contained in an object. Massa is a key concept in classical mechanics and other related subjects. In International Standards, SI, mass is measured in kilograms. The tools used to measure the mass is usually scales. Unlike the weight, mass is always ...
Read More »Pengujian Panel Kontrol Listrik
Pada industri-industri yang mempunyai beban produksi tinggi bila tejadi “down time” ini merupakan awal suatu gangguan yang menimbulkan kerugian yang besar persatuan waktu. Oleh karena itu harus ada personil yang mempunyai ketrampilan troubleshooting. Troubleshooting adalah suatu proses mendeteksi dan mendiagnosa segala kemungkinan yang dapat menyebabkan suatu peralatan produksi tidak dapat berfungsi sebagaimana mestinya. Dari pengalaman dilapangan terbukti, bahwa banyak teknisi ...
Read More »Alat Ukur Digital dan Analog
Untuk keperluan pengukuran arus telah tersedia berbagai jenis ampermeter, untuk pengukuran arus searah dan arus bolak-balik, dan untuk keperluan pengukuran presisi dan untuk keperluan panel listrik. Berikut ini diberikan contoh berbagai jenis ampermeter yang tersedia di pasaran untuk berbagai keperluan. Baik yang beroperasi secara analog, yakni menggunakan jarum penunjuk, dan yang beroperasi secara digital. Gambar 6.13 memperlihatkan ampermeter analog standar ...
Read More »Ampere-meter Function
One function Multimeter is its usefulness as Ampere-meter to measure the strong electric current between 0-1000 milli-Amperes (mA) or more depending on the specifications Multimeter. Measuring range switch in the position of the DCMA, measuring limit (range) at the 0.25 figure, 25, or 500 DCMA, as needed. The measurement results read on a scale of 0-250 DCV Board, A. On ...
Read More »Thermal Over Load Relay
Alat pengaman yang digunakan bila pada motor terjadi beban lebih disebut Thermal Over Load Relay (TOR/TOL) biasanya digandengkan dengan kontaktor, dipasaran ada juga pengaman beban lebih yang terintegrasi pada Motor Circuit Breaker. Relay ini biasanya dihubungkan pada kontaktor ke kontak utama 2, 4, dan 6 sebelum dihubungkan ke beban (motor). Gunanya untuk memberikan perlindungan terhadap motor dari kerusakan akibat beban ...
Read More »