Standard operating voltage for the solenoid coil mini relay using two types of resources, namely AC and DC.Untuk VAC voltage up to 240V, and voltage VDC to 120V.Kotak relay can be selected according to the purposes of the wearer, the type DPDT, TPDT, nominal FPDT.Arus varied, namely 3A, 5A and 7A. For the purposes of assembly and installation, there are ...
Read More »Author Archives: Taufiqullah
Hydraulic Steering Valve
This valve serves to regulate or control the direction of hydraulic fluid that will work moving the actuator. In other words, this valve serves to control the direction of movement of the actuator. Directional valves are named based on: Number of holes / working channel (port) Number of working positions Driving type valve Other additional names according to the characteristics ...
Read More »Menghitung Momen Dan Keseimbangan
Syarat keseimbangan untuk komponen gaya yang mempunyai titik tangkap sama dengan arah berlainan, adalah o Jumlah gaya pada sumbu X = nol (ΣX = 0); o Jumlah gaya pada sumbu Y = nol. (ΣY = 0 ). Sedangkan untuk gaya gaya yang mempunyai titik tangkap berlainan , dimana titik tangkap gaya satu dengan titik tangkap lainnya mempunyai jarak tertentu , ...
Read More »Hydraulic System Maintenance
Maintenance on the hydraulic system is very important, because it will greatly determine the operational life of each component, but on the maintenance of this hydraulic system usually lies in fluid, safety valve-valve; piston; motor and so on. On fluid maintenance is highly dependent on the condition of the oil, the oil change is cultivated after certain hours of use ...
Read More »Pemeliharan Katup Hidrolik dan Perbaikannya
Valve pada umumnya tidak menggunakan packing, hal ini disebabkan karena kebocorannya kecil. Akan tetapi karena fluida yang mengalir pada sistem hidrolik selalu diikuti oleh sejumlah kotoran, serabut, karat, dan lain-lain, maka lambat laun lubang-lubang valve ini akan tersumbat, tergores atau bahkan bocor. Jika hal ini sampai terjadi , akan menyebabkan tekanan fluida menjadi turun (drop). Untuk itu fluida hidrolik harus ...
Read More »Unit and Painting Style
The system generally accepted unit consists of: o System MKS unit, the unit has a style kgf o System British unit, the unit has a style lbf o SI unit system, has a style unit N (Newthon). Painting Style The style is abstract, can not be seen, by because they were to paint / describe a style there should be ...
Read More »